1.
Laboratory Medicine Online ; : 235-241, 2020.
Article | WPRIM | ID: wpr-836919

ABSTRACT

Background@#For effective management of blood components, periodic updates of the maximum surgical blood order schedule (MSBOS) using recent data are crucial. This study aimed to establish an updated MSBOS and red blood cell (RBC) mean transfusion units per patient according to the adjacent diagnosis related groups (ADRG) classification system. @*Methods@#This retrospective study was based on an audit of the medical records of inpatients at a tertiary hospital between January and December 2017. We investigated transfusion-related data to establish the MSBOS and determine the RBC mean transfusion units per patient according to the ADRG and compared these updated values with previous data. @*Results@#During the investigated period, a total of 5,607 RBC units were transfused in 17,382 patients. The revised MSBOS was similar to the previous MSBOS in most surgeries. Among the 130 ADRG codes analyzed, 34 codes showed an increase, while 96 codes showed a decrease in RBC mean transfusion units per patient, compared to data from 2007. Overall, the RBC mean transfusion units per patient in 2017 was 0.89 units less compared to that in 2007 after adjusting for age (95% CI: 0.853–0.912). @*Conclusions@#The revised MSBOS was similar to that of the previous versions. However, there were differences in the number of RBC transfusion units used in some surgeries and disease treatments compared to those in the past. Considering the changes within the medical environment, this study highlights the importance of periodic evaluation of MSBOS and RBC transfusion usage.

2.
Laboratory Medicine Online ; : 301-306, 2020.
Article in English | WPRIM | ID: wpr-902678

ABSTRACT

Background@#Multiple Allergo-Sorbent Test (MAST) allows simultaneous detection of specific IgE antibodies using multiple allergens, and it is commonly used for allergy screening. Phadiatop assay (Phadia AB, Sweden), including Phadiatop test and Phadiatop Infant test, is a variant of specific IgE test that covers a mixture of common allergens. We compared the clinical utility of Phadiatop assay with that of the MAST AlloScreen (LG Life Science, Korea). @*Methods@#A total of 218 samples classified by AlloScreen results were collected. Phadiatop test was performed on sera from 61 and 103 aeroallergen-positive and -negative subjects. Phadiatop Infant test was performed on sera from 54 and 103 food and aeroallergen-positive and -negative subjects. When the results of AlloScreen and Phadiatop assay were not identical, we confirmed them using ImmunoCAP (Phadia AB). @*Results@#The concordance rate between AlloScreen and Phadiatop test was 93.2% (κ=0.86, P<0.001). Eleven (6.7%) of 164 specimens showed discrepant results. The results of AlloScreen did not agree with those of ImmunoCAP. The concordance rate between AlloScreen and Phadiatop Infant test was 97.4% (κ=0.945, P <0.001). Four (2.5%) specimens showed negative results in AlloScreen and positive results in Phadiatop Infant test. Three cases were confirmed as positive and one case was not confirmed through ImmunoCAP. @*Conclusions@#There was excellent agreement between AlloScreen and Phadiatop assay. Phadiatop assay accurately detected sensitization to common food and aeroallergen mixes. Therefore, Phadiatop assay is recommended as a screening test for allergic diseases.

3.
Laboratory Medicine Online ; : 301-306, 2020.
Article in English | WPRIM | ID: wpr-894974

ABSTRACT

Background@#Multiple Allergo-Sorbent Test (MAST) allows simultaneous detection of specific IgE antibodies using multiple allergens, and it is commonly used for allergy screening. Phadiatop assay (Phadia AB, Sweden), including Phadiatop test and Phadiatop Infant test, is a variant of specific IgE test that covers a mixture of common allergens. We compared the clinical utility of Phadiatop assay with that of the MAST AlloScreen (LG Life Science, Korea). @*Methods@#A total of 218 samples classified by AlloScreen results were collected. Phadiatop test was performed on sera from 61 and 103 aeroallergen-positive and -negative subjects. Phadiatop Infant test was performed on sera from 54 and 103 food and aeroallergen-positive and -negative subjects. When the results of AlloScreen and Phadiatop assay were not identical, we confirmed them using ImmunoCAP (Phadia AB). @*Results@#The concordance rate between AlloScreen and Phadiatop test was 93.2% (κ=0.86, P<0.001). Eleven (6.7%) of 164 specimens showed discrepant results. The results of AlloScreen did not agree with those of ImmunoCAP. The concordance rate between AlloScreen and Phadiatop Infant test was 97.4% (κ=0.945, P <0.001). Four (2.5%) specimens showed negative results in AlloScreen and positive results in Phadiatop Infant test. Three cases were confirmed as positive and one case was not confirmed through ImmunoCAP. @*Conclusions@#There was excellent agreement between AlloScreen and Phadiatop assay. Phadiatop assay accurately detected sensitization to common food and aeroallergen mixes. Therefore, Phadiatop assay is recommended as a screening test for allergic diseases.

5.
Laboratory Medicine Online ; : 63-72, 2019.
Article in English | WPRIM | ID: wpr-760489

ABSTRACT

BACKGROUND: Blood culture is an important method for identifying infectious microorganisms and confirming that a selected antimicrobial treatment is appropriate. In this study, we investigated the annual changes in the frequencies of blood isolates and antibiotic susceptibility test (AST) results. METHODS: We created a large database comprising data on all patient-unique blood cultures obtained from January 2007 through December 2016. Blood specimens were cultured using the BD BACTEC FX system, and species identification and AST were performed using the VITEK 2 system. RESULTS: During the 10-year study period, a total of 203,651 blood culture results were collected. Of these, gram-positive cocci, gram-negative rods, and fungi were isolated in 2.15%, 0.55%, and 0.12% of the blood cultures, respectively. Escherichia coli was the most commonly isolated species (22.8%), followed by Staphylococcus epidermidis (16.8%), Klebsiella pneumoniae (8.1%), and Staphylococcus aureus (8.0%). Fungal species were isolated in 3.0% of all positive blood cultures. Candida albicans was the most commonly isolated species (1.1%), followed by Candida parapsilosis (0.6%). Methicillin resistance was seen in 55.2% of S. aureus isolates. The frequencies of vancomycin-resistant Enterococcus (VRE) and carbapenem-resistant Pseudomonas aeruginosa (CRPA) were 13.1% and 10.9%, respectively. The isolation rates of MRSA, VRE, and CRPA showed different patterns each year. CONCLUSIONS: Among the isolates, E. coli was the most common, followed by S. epidermidis and K. pneumoniae. This study represents a long-term analysis of bloodstream infections, and the results can be used to identify trends in the microorganisms isolated and their drug resistance.


Subject(s)
Bacteremia , Candida , Candida albicans , Drug Resistance , Enterococcus , Escherichia coli , Fungi , Gram-Positive Cocci , Klebsiella pneumoniae , Korea , Methicillin Resistance , Methicillin-Resistant Staphylococcus aureus , Methods , Pneumonia , Pseudomonas aeruginosa , Staphylococcus aureus , Staphylococcus epidermidis
6.
The Korean Journal of Internal Medicine ; : 1119-1128, 2018.
Article in English | WPRIM | ID: wpr-718020

ABSTRACT

BACKGROUND/AIMS: In multicenter clinical trials, laboratory tests are performed in the laboratory of each center, mostly using different measuring methodologies. The purpose of this study was to evaluate coefficients of variation (CVs) of laboratory results produced by various measuring methods and to determine whether mathematical data adjustment could achieve harmonization between the methods. METHODS: We chose 10 clinical laboratories, including Green Cross Laboratories (GC Labs), the central laboratory, for the measurement of total cholesterol, high density lipoprotein cholesterol (HDL-C), low density lipoprotein cholesterol (LDL-C), serum triglycerides, creatinine, and glucose. The serum panels made with patient samples referred to GC Labs were sent to the other laboratories. Twenty serum samples for each analyte were prepared, sent frozen, and analyzed by each participating laboratory. RESULTS: All methods used by participating laboratories for the six analytes had traceability by reference materials and methods. When the results from the nine laboratories were compared with those from GC Labs, the mean CVs for total cholesterol, HDL-C, LDL-C, and glucose analyzed using the same method were 1.7%, 3.7%, 4.3%, and 1.7%, respectively; and those for triglycerides and creatinine analyzed using two different methods were 4.5% and 4.48%, respectively. After adjusting data using Deming regression, the mean CV were 0.7%, 1.4%, 1.8%, 1.4%, 1.6%, and 0.8% for total cholesterol, HDL-C, LDL-C, triglyceride, creatinine, and glucose, respectively. CONCLUSIONS: We found that more comparable results can be produced by laboratory data harmonization using commutable samples. Therefore, harmonization efforts should be undertaken in multicenter trials for accurate data analysis (CRIS number; KCT0001235).


Subject(s)
Humans , Cholesterol , Cholesterol, HDL , Cholesterol, LDL , Creatinine , Glucose , Methods , Multicenter Studies as Topic , Research Design , Statistics as Topic , Triglycerides
8.
Annals of Laboratory Medicine ; : 349-351, 2017.
Article in English | WPRIM | ID: wpr-129955

ABSTRACT

No abstract available.


Subject(s)
Bacteremia , Korea
9.
Annals of Laboratory Medicine ; : 349-351, 2017.
Article in English | WPRIM | ID: wpr-129941

ABSTRACT

No abstract available.


Subject(s)
Bacteremia , Korea
10.
Annals of Clinical Microbiology ; : 74-79, 2017.
Article in English | WPRIM | ID: wpr-50238

ABSTRACT

Psychrobacter sanguinis has been described as a Gram-negative, aerobic coccobacilli originally isolated from environments and seaweed samples. To date, 6 cases of P. sanguinis infection have been reported. A 53-year-old male was admitted with a generalized tonic seizure lasting for 1 minute with loss of consciousness and a mild fever of 37.8℃. A Gram stain revealed Gram-negative, small, and coccobacilli-shaped bacteria on blood culture. Automated microbiology analyzer identification using the BD BACTEC FX (BD Diagnostics, Germany) and VITEK2 (bioMérieux, France) systems indicated the presence of Methylobacterium spp., Aeromonas salmonicida, and the Moraxella group with low discrimination. The GenBank Basic Local Alignment Search Tool and an Ez-Taxon database search revealed that the 16S rRNA gene sequence of the isolate showed 99.30% and 99.88% homology to 859 base-pairs of the corresponding sequences of P. sanguinis, respectively (GenBank accession numbers JX501674.1 and HM212667.1). To the best of our knowledge, this is the first human case of P. sanguinis bacteremia in Korea. It is notable that we identified a case based on blood specimens that previously had been misidentified by a commercially automated identification analyzer. We utilized 16S rRNA gene sequencing as a secondary method for correctly identifying this microorganism.


Subject(s)
Humans , Male , Middle Aged , Aeromonas salmonicida , Bacteremia , Bacteria , Databases, Nucleic Acid , Discrimination, Psychological , Fever , Genes, rRNA , Korea , Methods , Methylobacterium , Moraxella , Psychrobacter , RNA, Ribosomal, 16S , Seaweed , Seizures , Unconsciousness
11.
Laboratory Medicine Online ; : 182-188, 2017.
Article in English | WPRIM | ID: wpr-51171

ABSTRACT

BACKGROUND: The use of point-of-care (POC) devices for evaluating HbA1c is increasing; accordingly, comparisons between these devices and central laboratory methods are important. In the present study, we evaluated the analytical performance of the cobas b 101 analyzer for POC HbA1c testing. METHODS: The analytical quality of the cobas b 101 system was assessed based on repeatability, within-laboratory precision, linearity, and lot-to-lot reproducibility. Two specimen types, i.e., EDTA whole blood and capillary blood, were examined using the cobas b 101 system and the Variant II Turbo instrument. RESULTS: The coefficient of variation for within laboratory precision was 5.22% for a normal HbA1c level and 2.56% for a higher HbA1c level. The method showed good linearity, with a coefficient of correlation of 0.990. In a comparison of two different HbA1c disk lots, a strong correlation (r=0.986) and a mean %difference of −2.9% were observed. The cobas b 101 results using EDTA whole blood were strongly correlated with the Variant II Turbo results (r=0.958), with a mean %difference of 0.8%; the cobas b 101 results using capillary blood were strongly correlated with the Variant II Turbo results, using EDTA whole blood (r=0.976), with a mean %difference of 2.0%. A comparison between HbA1c levels in EDTA whole blood and capillary blood obtained using the cobas b 101 showed a strong correlation (r=0.985) and a mean %difference of 1.3%. CONCLUSIONS: The cobas b 101 analyzer is convenient for the measurement of HbA1c levels for diabetes management.


Subject(s)
Capillaries , Edetic Acid , Methods , Point-of-Care Systems , Point-of-Care Testing
12.
Annals of Laboratory Medicine ; : 427-433, 2016.
Article in English | WPRIM | ID: wpr-59853

ABSTRACT

BACKGROUND: Cotinine has been widely used as an objective marker to identify current smokers. We conducted this study to address the absence of Korean studies investigating the efficacy of immunoassays and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the detection of serum cotinine and to determine the optimal serum cotinine cut-off level for differentiating current smokers from nonsmokers. METHODS: Serum specimens were obtained from 120 subjects. They were randomly chosen to represent a broad distribution of urine cotinine levels based on a retrospective review of questionnaires and results of urine cotinine levels. We determined serum cotinine levels using the IMMULITE 2000 XPi Immunoassay System (Siemens Healthcare Diagnostics Inc., USA) and LC-MS/MS (API-4000, Applied Biosystems, USA). Correlation was analyzed between IMMULITE serum cotinine, urine cotinine, and LC-MS/MS serum cotinine levels. ROC curve was analyzed to identify the optimal IMMULITE serum cotinine cut-off level for differentiating current smokers from nonsmokers. RESULTS: IMMULITE serum cotinine levels correlated with both urine cotinine and LC-MS/MS serum cotinine levels, with correlation coefficients of 0.958 and 0.986, respectively. The optimal serum cotinine cut-off level for distinguishing current smokers from nonsmokers was 13.2 ng/mL (95.7% sensitivity, 94.1% specificity) using IMMULITE. CONCLUSIONS: This is the first study to investigate the use of LC-MS/MS for the measurement of serum cotinine and to determine the optimal serum cotinine cut-off level for the IMMULITE immunoassay. Our results could provide guidelines for differentiating current smokers from nonsmokers in the Korean population.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Area Under Curve , Asian People , Chromatography, High Pressure Liquid , Cotinine/blood , Immunoassay , ROC Curve , Republic of Korea , Retrospective Studies , Smoking , Surveys and Questionnaires , Tandem Mass Spectrometry
13.
Intestinal Research ; : 178-182, 2016.
Article in English | WPRIM | ID: wpr-168224

ABSTRACT

BACKGROUND/AIMS: To prevent the transmission of pathogens by endoscopes, following established reprocessing guidelines is critical. An ideal reprocessing step is simple, fast, and inexpensive. Here, we evaluated and compared the efficacy and safety of two disinfectants, a tertiary amine compound (TAC) and ortho-phthalaldehyde (OPA). METHODS: A total of 100 colonoscopes were randomly reprocessed using two same automated endoscope reprocessors, according to disinfectant. The exposure time was 10 minutes for 0.55% OPA (Cidex® OPA, Johnson & Johnson) and 5 minutes for 4% TAC (Sencron2®, Bab Gencel Pharma & Chemical Ind. Co.). Three culture samples were obtained from each colonoscope after reprocessing. RESULTS: A total of nine samples were positive among the 300 culture samples. The positive culture rate was not statistically different between the two groups (4% for OPA and 2% for TAC, P=0.501). There were no incidents related to safety during the study period. CONCLUSIONS: TAC was non-inferior in terms of reprocessing efficacy to OPA and was safe to use. Therefore, TAC seems to be a good alternative disinfectant with a relatively short exposure time and is also less expensive than OPA.


Subject(s)
Colonoscopes , Disinfectants , Endoscopes , o-Phthalaldehyde
14.
Journal of Laboratory Medicine and Quality Assurance ; : 101-109, 2015.
Article in English | WPRIM | ID: wpr-104671

ABSTRACT

BACKGROUND: The e602, a module of the recently released cobas 8000 modular analyzer series, is an automated system for immunoassays. In this study, we evaluated its analytical performance using 17 immunoassay analytes. METHODS: The Clinical Laboratory Standards Institute guidelines were used to determine the efficiency of the cobas 8000 e602 based on its precision, linearity, assay comparison, and reference range validation. Performance analyses were completed using two levels of quality control materials and pooled sera from our institution. The performance of the cobas 8000 e602 was compared to that of the modular analytics E170. Statistical analyses were performed using Excel 2010 (Microsoft Co., USA) and EP Evaluator Release 10 (Data Innovations, USA). RESULTS: For all analytes, except level 1 total vitamin D, the coefficients of variation were 0.975 for all analytes. The reference range validation was also within the allowable criteria. CONCLUSIONS: Taken together, these findings demonstrate that the cobas 8000 e602 analyzer has good precision, linearity, performance comparison, and reference range validation. Thus, e602 is a useful module of the cobas 8000 modular analyzer series.


Subject(s)
Immunoassay , Quality Control , Reference Values , Vitamin D
17.
Laboratory Medicine Online ; : 112-115, 2014.
Article in Korean | WPRIM | ID: wpr-76365

ABSTRACT

Infants with Down syndrome have increased incidences of transient abnormal myelopoiesis (TAM) and acute leukemia, which are usually associated with acute megakaryoblastic leukemia (AMKL). A 5-day-old girl with Down syndrome was diagnosed with TAM; 4 months later, acute leukemic transformation was suspected. Bone marrow (BM) examination was performed, and the infant was diagnosed with acute leukemia (80% blasts). Although BM aspirates showed the presence of megakaryocytic blasts with cytoplasmic blebs, flow cytometry analysis revealed that they were negative for cells with CD41a and CD61 immunophenotypes. Further analysis revealed that the megakaryocyte-related marker CD42a was positive in 57% of blasts. Morphologic and immunophenotypic features are required to establish the lineage of megakaryocytic blasts, which are necessary for diagnosing AMKL. As most cases of AMKL were positive for CD41 and/or CD61 markers, their presence was evaluated during routine analysis. In order to identify the immunophenotypic features of AMKL in an infant with Down syndrome, we performed additional flow cytometry for CD42a, one of the megakaryocytic markers, and were able to assist in the early diagnosis of AMKL, as well as to use CD42a as an effective follow-up marker.


Subject(s)
Female , Humans , Infant , Blister , Bone Marrow , Cytoplasm , Down Syndrome , Early Diagnosis , Flow Cytometry , Follow-Up Studies , Incidence , Leukemia , Leukemia, Megakaryoblastic, Acute , Myelopoiesis
20.
Laboratory Medicine Online ; : 97-103, 2013.
Article in Korean | WPRIM | ID: wpr-82593

ABSTRACT

BACKGROUND: In support of safe and appropriate utilization of blood products, the Korean Ministry of Health and Welfare and the Korean Society of Blood Transfusion developed transfusion guidelines in 2009. We evaluated the appropriateness of blood transfusions on the basis of these proposed guidelines. METHODS: We investigated the awareness of the 2009 proposed guidelines and the transfusion guidelines currently in use through a questionnaire administered to the physicians of a tertiary care hospital. We provided the 2009 proposed transfusion guidelines through summarized pop-ups for each blood product that appeared in the hospital information system whenever a physician ordered blood products, and promoted the guidelines by posting it on the bulletin board and the hospital information system for one month. Evaluation of the appropriateness of blood transfusion was conducted by reviewing the medical records of patients who were transfused within one month before and one month after the promotion. Further, we also examined the rates of blood wastage and return. RESULTS: Rates of appropriately transfused blood products changed from 29.4% to 33.1% for red blood cells, from 16.9% to 68.9% for platelets, and from 54.8% to 33.3% for fresh frozen plasma. The decreased appropriate transfusion rate of fresh frozen plasma might be due to the small number of transfusions performed during the short study period. The rates of blood wastage and return decreased from 1.77% to 1.21% and from 3.91% to 3.00%, respectively. CONCLUSIONS: Promotion of the new transfusion guidelines lowered the incidence of inappropriate transfusions. Continuous promotion and establishment of these guidelines after adjustments according to the status of each hospital are necessary.


Subject(s)
Humans , Blood Platelets , Blood Transfusion , Erythrocytes , Hospital Information Systems , Incidence , Medical Records , Plasma , Surveys and Questionnaires , Tertiary Healthcare